43
Lexmark 13T0101
Xerox 113R296
Samsung ML5000/TD55K
REQUIRED FOR A SUCCESSFUL REFILL:
Toner (Uni-Kit Formula 6A)
1 funnel cap
Hole Making Tool
Replacement Fuse
General Refilling Procedures:
Use a screwdriver to remove the three small screws holding the end cap in place. In
order to remove the end cap the drum shutter arm must be disengaged from a hole in
the end cap. Open the drum shutter door and disengage the pin from the side of the
cartridge. Now carefully wiggle the end cap loose. Press down on the existing fuse.
Use a screwdriver and gently but firmly press down on the fuse from the top side of
the end cap. Turn the end over and remove the fuse. Press the replacement fuse back in
place until it snaps in. Now reassemble the end cap and reinsert the drum shutter arm
and replace the screws.
Rest the Hole Making Tool on its stand and plug into an outlet. Wait 3 full minutes
before using. Position the copper bit on the cartridge in the spot indicated by the pho-
tograph and push gently until it melts a hole in the cartridge. Make sure to keep the
hole on the flat surface of the cartridge and not on the curved edge. Remove the tool,
place it back on its stand and unplug it. If the small piece of plastic has fallen into the
cartridge, it must be removed, as this can damage your cartridge or cause print defects.
If the piece remains in the tool, wait for the tool to cool down and pry it out.
Before opening the bottle of toner, turn it upside down and tap it on a table to loosen
the toner and allow it to flow freely. Remove the cap and pull the seal off the bottle.
Attach the funnel cap making to sure it is on tightly. Tilt the funnel cap toward the
filling hole and insert it into the hole. If the toner stops flowing before the cartridge is
full, simply remove the toner, close the cap, turn the bottle upside down and tap it on
a table. Once the cartridge is full, seal the hole with the plug by twisting it until it is
completely seated.
Do not press down on the plug since the cartridge is resting on a table this can actually
damage the photo-optic drum. Instead hold one end of the cartridge up off the table
and twist the plug until it fully sealed. Now gently shake the cartridge side to side to
distribute the toner.
make